Owner’s manual, Service procedures – Desa BY150ECB 150,000 Btu/Hr 110v/50 Hz User Manual

Page 7

Advertising
background image

7

104001

OWNER’S MANUAL

SERVICE
PROCEDURES

UPPER SHELL REMOVAL

1.

Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.

2.

Lift upper shell off.

3.

Remove fan guard.

FAN

IMPORTANT:

Remove fan from motor

shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.

1.

Remove upper shell (see above).

2.

Use 1/8" allen wrench to loosen set-
screw which holds fan to motor shaft.

3.

Slip fan off motor shaft.

4.

Clean fan using soft cloth moistened
with kerosene or solvent.

5.

Dry fan thoroughly.

6.

Replace fan on motor shaft. Place fan
hub flush with end of motor shaft (see
Figure 6).

7.

Place setscrew on flat of shaft. Tighten
setscrew firmly (4.5-5.6 n-m/40-50
inch-pounds).

8.

Replace fan guard and upper shell.

AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS

1.

Remove upper shell (see above).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 5).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

Figure 6 - Fan Cross Section

Figure 5 - Upper Shell Removal

Upper Shell

Fan
Guard

Fan

Setscrew

Motor
Shaft

Flush

Figure 7 - Air Output, Air Intake, and Lint
Filters

Fan Guard

Air Intake Filter

Air Output Filter

Filter End Cover

Lint Filter

Motor

PUMP PRESSURE
ADJUSTMENT

1.

Remove pressure gauge plug from filter
end cover.

2.

Install accessory pressure gauge (part
number HA1180).

3.

Start heater (see Operation, page 4).
Allow motor to reach full speed.

4.

Adjust pressure. Turn relief valve to
right to increase pressure. Turn relief
valve to left to decrease pressure. See
specifications at right for correct pres-
sure for each model.

5.

Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.

Relief
Valve

Pressure
Gauge
Plug

Figure 8 - Pressure Gauge Plug Removal

Pump

Model

Pressure

150,000 Btu/Hr

4.8 PSI (.331 bar)

Figure 9 - Adjusting Pump Pressure

Pressure
Gauge