Sloan 910 Royal Exposed 900 Hydraulic Series User Manual
Page 4

4
B
Install valve actuator housing onto flushometer valve body. Tighten
housing nut with a wrench.
Insert actuator cartridge into flushometer valve body.
A
C
Cut off excess tubing with plastic tube cutter (PTC) so that there will
be about 3” to 4” (76 to 102 mm) of slack when connected to valve
actuator. If “L” and “O” marketings on the tubing will be cut off, then
remark tubing appropriately to retain identification.
D
Slide plastic tubing into its corresponding valve actuator fitting. Pull
tubing to make sure connection is secure. (Tubing can be removed by
pressing on blue connection button to release.)
C
Slide chrome sleeve (threaded end first) over
plastic tubing. Thread onto valve actuator until chrome sleeve is tight
against valve actuator housing.
D
Slide flange and cover plate over plastic tubing and onto chrome
sleeve.
BAK-CHEK
®
CONTROL STOP
FLUSHOMETER
VALVE BODY
HY-83-A
ACTUATOR
CARTRIDGE
VALVE
ACTUATOR
HOUSING
QUICK
CONNECT
FITTINGS (2)
PLASTIC
TUBES
CHROME
SLEEVE
FLANGE
COVER PLATE
VACUUM
BREAKER TUBE
WITH REPAIR KIT
HOUSING
NUT
Align flushometer Body on top of vacuum
breaker flush connection. Measure distance
from valve actuator Housing to finished wall. Cut
chrome sleeve adding an additional 1” (25 mm)
to the previously measured distance.
IMPORTANT: DO NOT CUT THREADED END OF
CHROME SLEEVE. ONLY CUT NON-THREADED END.
A
B
Remove flushometer body from top of
vacuum breaker flush connection.
E
Run plastic tubing through wall hole to push button actuator location.
(If installing HY-72-A push button actuator, run plastic tubing through
electrical box and conduit and out through the electrical box at push
button actuator location.
F
Insert adjustable tailpiece into control stop.
Lubricate o-ring seal with water. Hand
tighten tailpiece coupling.
MAXIMUM ADjUSTMENT OF
THE SLOAN ADjUSTABLE
TAILPIECE IS 1/2” (13 MM)
IN OR OUT FROM THE
STANDARD 4-3/4” (121 MM)
(C/L OF FLUSHOMETER TO
C/L OF CONTROL STOP). IF
ROUGH-IN MEASUREMENT
EXCEEDS 5-1/4” (133 MM),
CONSULT FACTORY FOR
LONGER TAILPIECE.
G
Align flushometer body on top of vacuum
breaker flush connection. Hand tighten
vacuum breaker coupling.
H
Align flushometer body. Using a wrench, securely tighten couplings in
order given:
(1)
tailpiece coupling,
(2)
vacuum breaker coupling and
(3)
spud coupling. Then tighten valve actuator housing nut securely.
I
With flushometer
body aligned on top
of vacuum breaker
flush connection,
assemble cover plate
to plaster ring with
hex head screws.
Slide flange against
cover plate.
Mount Wall Flange onto Cover Plate using (2) Flathead Screws,
Lockwashers and Nuts provided. Tighten Fasteners securely.
A
Insert extension Stem into extension Adapter and thread extension
Adapter onto Push Button Actuator.
B
Insert threaded end of Push Button Actuator Assembly through Cover
Plate Assembly. Fasten to Plate with Nut. Tighten securely.
C
Place Brass Insert into black Push Button. Concave side of Brass Insert
must face outward of Push Button.
D
Mount Cover Plate Assembly onto electrical box cover using the four (4)
Screws provided.
G
Attach plastic tubing. See: Steps to attach plastic tubing on next page.
F
Insert black Push Button into Button Flange. Place Spring against
Brass Insert of Push Button. Install Push Button Assembly onto Cover
Plate. Secure with Setscrew located on Button Flange.
E
BUTTON
FLANGE
BRASS INSERT
SPRING
NUT
COVER PLATE SCREWS (4)
EXTENSION ADAPTER
EXTENSION STEM
ACTUATOR
WALL
SETSCREW
PUSH BUTTON
FLATHEAD SCREWS (2)
WALL FLANGE
COVER PLATE
LOCKWASHERS (2)
NUTS (2)
PLASTIC
TUBING
UNIVERSAL
(2) GANG
ELEC. BOX
1-5/8” D x
4-1/2” H x
6-13/16”
W (NOT
SUPPLIED
BY SLOAN)
(2) GANG ELEC. BOX DEVICE COVER 3/4” RAISED
x 4-3/4” H x 7-1/16” W (NOT SUPPLIED BY SLOAN)
MEASURE DISTANCE
AND ADD 1” (25 mm)
4-1/4”
(108 mm)
MIN.
5-1/4”
(133 mm)
MAX.
1-1/2” (38 mm)
— DIMENSION
MUST BE HELD
TO 1/8” (3 mm)
2-9/16”
(65 mm)
IMPORTANT: USE A SLOAN A-50 SUPER WRENCH™, SLOAN A-109
PLIER WRENCH OR SMOOTH JAWED SPUD WRENCH TO SECURE ALL
COUPLINGS. THIS WILL ELIMINATE DAMAGE TO CHROME OR SPECIAL
FINISH THAT NORMALLY OCCURS WHEN SLIP-JOINT PLIERS, PIPE
WRENCHES OR OTHER “TOOTHED” TOOLS ARE USED.
ACTUATOR
ASSEMBLY
FLUSHOMETER
BODY
VACUUM
BREAKER
COUPLING)
VACUUM
BREAKER
FLUSH
CONNECTION
ADjUSTABLE
TAILPIECE
TAILPIECE
COUPLING
CONTROL
STOP
O-RING
G-44
FRICTION
RING
SPUD
COUPLING
4-3/4”
(121 mm)
C/L
FIXTURE
C/L
SUPPLY
VACUUM
BREAKER
REPAIR KIT
1
3
2
4 - INSTALL VALVE ACTUATOR
5 - INSTALL FLUSHOMETER
6A - INSTALL PUSH BUTTON ACTUATOR (HY-72-A SIDE WALL (SW VARIATION) PUSH BUTTON ACTUATOR)
OBSERVE “L” AND “O” MARKINGS ON TUBING.
TUBING MUST BE CONNECTED TO CORRESPONDING
“L” AND “O” MARKINGS ON VALVE ACTUATOR.
!!! IMPORTANT !!!
- 911 Royal Exposed 900 Hydraulic Series 986 Royal Exposed 900 Hydraulic Series 920 Royal Exposed 900 Hydraulic Series 917 Royal Exposed 900 Hydraulic Series 980 Royal Exposed 900 Hydraulic Series 922 Royal Exposed 900 Hydraulic Series 921 Royal Exposed 900 Hydraulic Series 913 Royal Exposed 900 Hydraulic Series 915 Royal Exposed 900 Hydraulic Series 916 Royal Exposed 900 Hydraulic Series