USING RS-232 CONTROL (continued)

NOTES:
 When successful, commands #1-5 will acknowledge by sending the

checksum with nibbles swapped & <CR><LF>
e.g. checksum of 0x24 acknowledges with <0x42><CR><LF>

 All bytes in examples are ASCII characters unless they are contained in

brackets <>

 Calculating the Checksum: <CHK> stands for CHECKSUM: the <CHK>

value is calculated by performing an XOR of the full command string

*For example: //F00M12I03 will XOR to the hexadecimal value

0x42, therefore the value of <CHK> is 0x42

 <CHK> is the logical exclusive OR (XOR) of all previous bytes.

 <CR> is carriage return (0x0D), all commands sent from PC end with

<CR>.

 <LF> is line feed (0x0A)

 xx is the frame address of the router e.g. “00” or “01”
From the factory the address is always “00”, however it can be changed
with command #5 above.

 yy is the Output (monitor) number. e.g. “01”

 zz is the Input number. e.g. “06” or “16”

 nn is the Matrix’s new frame address

USING THE FRONT PANEL CONTROL

Front Panel Buttons

To lock the front panel buttons to avoid any accidental changes, press ESC
+ MENU + ENTER + SWITCH at the same time. The display will indicate that
it is locked. Repeat the procedure to unlock the front panel.

During normal operation, you will see a list of ports on the front panel
display.

Default Display

To assign an output to an input, press SWITCH. A blinking block cursor will
appear. Use UP and DOWN to select the input that you would like to assign.
Once the cursor is over the desired input port, press ENTER to enter editing
mode. Press UP and DOWN to select the output port. Once you have se-
lected an output, press ENTER to save the configuration. To escape from
editing mode, press ESC.