31

Use Table I to determine the proper value for CV 113.

Step 9. Resetting CVs or Starting Over
Occasionally, something goes wrong and the DSD-LC will not respond as expected. Usually, this
is caused by one or more CVs being programmed to the wrong value. The CVs can be quickly
reset to their factory default values using the following procedure.

1.

Program CV 30 to 2 using either Service Mode or Operations Mode.

2.

Place locomotive on a powered section of track. If locomotive is already on the main-
line, cycle power to the decoder by turning power to the track off and then back on.

3.

You should immediately observe the headlight and backup light flashing together. If
not, repeat step 1 and 2.

4.

After about five seconds, the headlight and backup light will flash back and forth at an
increased rate indicating that the CVs have been reset.

5.

You may wait another 25 seconds for the DSD to resume normal operation or bypass
the waiting period by turning power to the locomotive off and then back on.

6.

The DSD-LC should now respond to short address 3 just as it did when it was first
unpacked.