Installing blower accessory in 36" or 42" firebox, Continued – Desa Ga3750a User Manual

Page 4

Advertising
background image

108319-01B

4

For more information, visit www.desatech.com

For more information, visit www.desatech.com

4.

Attach green ground wire from power cord to blower housing
using screw provided (see Figure 9). Tighten screws securely.

5.

Place the blower against the lower rear wall of the firebox outer
wrapper with the exhaust port directed upward. Align the holes
in top mounting tabs of blower with holes in wall of wrapper
(see Figure 9). Using 2 screws provided, mount blower and
tighten screws securely.

6.

Be certain that all wire terminals are securely attached to ter-
minals on blower motor and that the screw retaining the green
ground wire is tight.

7.

Locate the plastic hole plug installed in the 3/8" diameter open-
ing in the lower right side of the firebox front panel (see Fig-
ure 10). Remove the plastic plug and discard.

INSTALLING BLOWER
ACCESSORY IN 36" OR 42"
FIREBOX

Continued

8.

Place speed control against inner wall of front panel, pushing
the plastic control shaft forward through the opening.

9.

While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise un-
til it is tight against front panel. Place control knob provided
on shaft (see Figure 11).

10. Turn on power to duplex outlet if previously turned off per the

warning in column 2, page 3.

11. Plug in blower power cord.

a. If your firebox is installed as a freestanding unit with an

accessory mantel, determine whether the power cord will
exit the left side or the right side of the firebox. Install 1 plas-
tic bushing provided into the 1

1

/

2

" hole in the floor support on

the exit side. Install the second plastic bushing provided into
the 1

1

/

2

" hole in the outer casing through which the power

cord will exit (see Figures 10 and 12). Route power cord
through both plastic bushings and plug the power cord into a
wall receptacle near the firebox.

Figure 9 - Mounting Blower to Firebox

Blower

Screws

Top Mounting
Tab

Exhaust Port

Lower Rear Wall of
Firebox Wrapper

Screw

Figure 10 - Installing Plastic Bushing for Power Cord

1

1

/

2

" Hole

Plastic
Bushing

Plastic
Hole Plug

Figure 11 - Attaching Speed Control to Firebox

Speed Control

Control Shaft

Locknut

Control Knob

Va

ria

ble

Fa

n S

wi

tch

W

hit

e

W

hit

e

Bla

ck

Gr

ee

n

On

11

0/1

15

V.

A.

C.

Blo

we

r

Mo

to

r

Bla

ck

Bla

ck

Bla

ck

Of

f

Figure 12 - Location of Wiring Diagram Decal

Wiring Diagram Decal 12"
in Front of Blower

Floor
Supports

1

1

/

2

" Hole

INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX