Fc100 - floating point fast fourier transform – Sundance FC100 v.2.3 User Manual
Page 15
Advertising

FC100 - Floating Point Fast Fourier Transform
v2.3
Fast Fourier Transform product manual
October 2005
www.sundance.com
- 15 -
Data input memory bank swap
Figure 5 : Memory bank swap
When the core requires a new pass to be computed, it needs to get the results data from
the previous pass as input data. A pass transition is indicated by an inversion of the
din_bank signal. This signal can be used to multiplex the memory banks connected to the
core during processing.
Advertising