1 location of smt391 test points, 8 power supply, Power supply – Sundance SMT791 User Manual
Page 21
Advertising

7.1 Location of SMT391 Test Points
The following figure shows the location of the voltage test points on the SMT391.
Figure 14: Voltage Test Point Locations.
8 Power Supply
The following voltages are required by the SMT391 and must be supplied over the
daughter card power connector.
Voltage
Current
Required
D+3V3_IN 2.0
A
D+5V0_IN 500
mA
D+12V0_IN 250
mA
D-12V0_IN 250
mA
DGND
Figure 15: SMT391 Power Supply Voltages.
The following table lists the internal SMT391 voltages that are derived from the
voltages that are provided over the daughter card power connector.
Voltage
Description
D+3V3
Derived from D+3V3_IN
D+2V25
Derived from D+3V3 on
SMT391
User Manual SMT791
Page 21 of 21
Last Edited: 12/10/2010 09:52:00
Advertising