1 location of smt391 test points, 8 power supply, Power supply – Sundance SMT791 User Manual

Page 21

Advertising
background image

7.1 Location of SMT391 Test Points

The following figure shows the location of the voltage test points on the SMT391.

Figure 14: Voltage Test Point Locations.

8 Power Supply

The following voltages are required by the SMT391 and must be supplied over the
daughter card power connector.

Voltage

Current
Required

D+3V3_IN 2.0

A

D+5V0_IN 500

mA

D+12V0_IN 250

mA

D-12V0_IN 250

mA

DGND

Figure 15: SMT391 Power Supply Voltages.


The following table lists the internal SMT391 voltages that are derived from the
voltages that are provided over the daughter card power connector.

Voltage

Description

D+3V3

Derived from D+3V3_IN

D+2V25

Derived from D+3V3 on
SMT391

User Manual SMT791

Page 21 of 21

Last Edited: 12/10/2010 09:52:00