Digi 62533 User Manual

Page 6

Advertising
background image

TB-6128 Page 6 of 7

Revision 10/06

© 2005 DESCO INDUSTRIES INC.

Employee Owned

Specifications and Dimensions:






Figure 4.



Troubleshooting:

• Link LED or ACT not turning on when unit is powered

-

Power down unit, re-power unit and push and hold reset button for 10-12 seconds.

• Software cannot find or conflicts within comports

-

Make sure you have the Diagnostic Loop Back securely connected to the serial port of model 50461.

-

Make sure Ethernet cable is not defective or incorrectly wired.

-

If you have a Lantronix comport redirector installed on the same computer, you will need to un-install the
software.

-

• Unit not communicating with software

-

Make sure dip is set to dip 1 on and dip 2 to 4 is off.

-

Make sure Ethernet cable is not defective or incorrectly wired.

-

Make sure the DB9 Adapter is securely connected to the serial port of model 50461

-

Make sure you have the 24” data cable from the Ethernet connect to right port of

Smartlog X3 (labeled RS-232)






Operation Temperature:
Ambient temperature: 10ºC to 45ºC (50ºF to 131ºF)
Relative humidity: 5% to 90% (non-condensing)

Power Requirement:
9-30Vdc @ 0.5A max


Regulatory Approval:
FCC Part 15 Subpart B, Class A
EN55022, Class A
EN55024
EN61000-3-2,3
UL60950
CAN/CSA C22.2 No.60950
EN60950

Dimensions:
Length:

3.882” in / 9.860cm

Width:

1.679” in / 4.264cm

Depth:

0.983” in / 2.496cm

Weight:

2.29 oz / 65 g