Teac MX-2424 Installation v1.01 User Manual

Teac Audio

Advertising
background image

Installing The MX-2424

When mounting MX-2424's on top of each other in a rack

the feet may be removed by unscrewing them.

To replace the feet:

1. Insert the fastener into the foot

2. Snap the fastener & foot back into the hole in the bottom of the MX-2424 chassis

3. Snap the screw into the fastener's hole

Multiple units can be mounted on top of each other when forced air rack ventilation is provided.

a one inch clearance is required on both sides of the MX-2424 (even in single-unit installations).

In facilities with raised computer-room style flooring, a ventilation opening in the floor is recom-

mended. In no case should the internal rack temperature ever exceed 100 degrees Fahrenheit

(43 degrees Centigrade) during operation (as measured at the rear of any MX-2424 in the system).

Advertising