OBSERVED PROBLEM

ODS/pilot lights but flame goes

out when control knob is re-

leased

Burner does not light after ODS/

pilot is lit

Delayed ignition of burner

Burner backfiring during com-

bustion

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in for 30

seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat

ignition operation

4. Fully open equipment shutoff

valve

5. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 12) or replace ODS/

pilot assembly

6. Hand tighten until snug, then

tighten 1/4 turn more

7. Replace pilot assembly

8. Replace control valve

1. Contact local natural or

propane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 12) or

replace burner orifice(s)

3. Replace burner orifice(s)

4. Put remote selector in ON

position

5. See Wiring Diagram, page

17)

1. Contact local natural or

propane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 12)

1. Clean burner (see Cleaning

and Maintenance, page 12) or

replace burner orifice

2. Replace damaged burner

3. Replace gas regulator

POSSIBLE CAUSE

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered

4. Equipment shutoff valve not

fully open

5. Pilot flame not touching

thermocouple, which allows

thermocouple to cool,

causing pilot flame to go

out. This problem could be

caused by one or both of the

following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/Pilot

6. Thermocouple connection

loose at control valve

7. Thermocouple damaged

8. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Burner orifice(s) diameter

too small

4. Remote selector in OFF

position (Remote use only)

5. Wire disconnected from gas

control (Remote use only)

1. Manifold pressure is too

low

2. Burner orifice(s) clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

TROUBLESHOOTING