Installation – Desa VTDMV24PA User Manual

Page 9

Advertising
background image

www.desatech.com

114926-01B

9

INSTALLATION

Continued

Figure 8 - Equipment Shutoff Valve

Equipment
Shutoff
Valve

Open

Closed

Figure 10 - Checking Gas Joints

(Natural Gas Only)

Control Valve
Location

Equipment
Shutoff Valve

Propane/LP
Supply Tank

Equipment
Shutoff Valve

Gas Meter

Figure 9 - Checking Gas Joints

(Propane/LP Gas Only)

Control Valve
Location

6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected fit-

tings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 8).
2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter to equipment

shutoff valve for natural gas or propane/LP supply

to equipment shutoff valve for propane/LP (see

Figure 9 or 10). Apply noncorrosive leak detection

fluid to all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Appliance Gas
Connections
1. Open equipment shutoff valve (see Figure 8).
2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Make sure control knob of appliance is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas control (see Figure 9 or 10). Apply

noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light appliance (see Operating Appliance,

page 10) Check all other internal joints for

leaks.

7. Turn off appliance.

PLACEMENT OF LOOSE EMBERS

CAUTION: Do not place

any loose embers around pilot

assembly.

Two bags of loose embers are provided with this

unit. For this installation use the embers that are

approximately 1" square in size. If needed, larger

embers can be broken to size. These embers aid

in concealing the burner pan, directing flames

through the ember bed, quiet operation of the unit

and gives a natural random flame pattern.
Place embers as follows:
1. Place embers around the center ember bed or

ember pod.

2. Place individual embers on their edge (not flat)

along the top of the burner pan. This aids in

directing flames from the burner through the

ember bed.

Note:

Too many embers or embers placed flat

along burner pan can suppress the flames.

3. When unit is lit, check flames for random appear-

ance and ember bed glowing red-orange in color

(see Burner Flame Pattern, page 11). If this is

not happening, either add, remove or reposition

loose embers. IMPORTANT: Turn unit off and

let cool before repositioning loose embers.

Figure 11 - Placement of Embers

Advertising
This manual is related to the following products: