OPERATION

Continued

MANUAL CONTROL INFRARED

MODELS ONLY

TO SELECT

HEATING LEVEL

WARNING: When running

heater, set control knob at LOW

or HIGH locked positions for

double burner heater or ON po-

sition for single burner heater.

Never set control knob between

locked positions. Poor combus-

tion and higher levels of carbon

monoxide may result.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Control Double
Knobs Burners

ON

OFF

PILOT

IGN

OFF

Control Single
Knob Burner

Figure 20 - Burner Patterns

INSPECTING BURNER

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Figure 21 - Correct Pilot Flame Pattern

Figure 22 - Incorrect Pilot Flame Pattern

Slightly press in control knob and turn counter-
clockwise

to the LOW or HIGH positions

for double burner heater or ON position for
single burner heater.
IMPORTANT: Release downward pressure
while turning control knob. Control knob will
lock at the desired position.

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern.
Figure 22 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 22
• turn heater off (see To Turn Off Gas to Ap-

pliance, page 14)

• see Cleaning, page 17
Note: The pilot flame on natural gas units will
have a slight curve, but flame should be blue
and have no yellow or orange color.