TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode positioned

wrong

2. Ignitor electrode broken
3. Ignitor electrode not con-

nected to ignitor cable

4. Ignitor cable pinched or

wet

5. Piezo ignitor nut is loose

6. Broken ignitor cable

7. Bad piezo ignitor

1. Gas supply turned off or

equipment shutoff valve
closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

OBSERVED PROBLEM

When ignitor button is
pressed, there is no spark at
ODS/pilot

When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition

REMEDY

1. Replace pilot assembly

2. Replace pilot assembly
3. Reconnect ignitor cable

4. Free ignitor cable if pinched

by any metal or tubing.
Keep ignitor cable dry

5. Tighten nut holding piezo

ignitor to heater cabinet.
Nut is located inside heater
cabinet at top

6. Replace ignitor cable

7. Replace piezo ignitor

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while

in PILOT position

4. Continue holding down

control knob. Repeat ignit-
ing operation until air is
removed

5. Contact local propane/LP

gas company

6. Clean ODS/pilot (see Clean-

ing, page 17) or replace
ODS/pilot assembly

7. Replace gas regulator