Vx/hdx/mx router snmp traps, Low vcc warning begin and clear, High tx bias warning begin and clear – Thinklogical Router SNMP Traps User Manual

Page 3: Low tx bias warning begin and clear

Advertising
background image

Vx/Hdx/Mx Router SNMP Traps

Low Vcc Warning

Begin and Clear

A SFP module has the ability to monitor and alarm on a high or low Vcc voltage reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs.
This notification is sent when bit 4 of byte 116 in the real-time diagnostic registers changes from 0
to 1 (Begin) or from a 1 to a 0 (Clear).

This bit is set when the internal supply voltage to the SFP falls below the low voltage warning
level. The SFP voltage is stored at bytes 98 & 99 of the SFP diagnostic register table.

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowVccWarning

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

High TX Bias Warning

Begin and Clear

A SFP module has the ability to monitor and alarm on a high or low TX bias current reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs.
This notification is sent when bit 3 of byte 116 in the real-time diagnostic registers changes from 0
to 1 (Begin) or from a 1 to a 0 (Clear).

This bit is set when the internal current to the SFP transmitter exceeds the high current warning
level. The SFP TX current value is stored at bytes 100 & 101 of the SFP diagnostic register table.

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighTxBiasWarning

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

Low TX Bias Warning

Begin and Clear

A SFP module has the ability to monitor and alarm on a high or low TX bias current reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs.
This notification is sent when bit 2 of byte 116 in the real-time diagnostic registers changes from 0
to 1 (Begin) or from a 1 to a 0 (Clear).

This bit is set when the internal current to the SFP transmitter falls below the low current warning
level. The SFP TX current value is stored at bytes 100 & 101 of the SFP diagnostic register table.

Objects:

1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowTxBiasWarning

4: sysContact
5: sysDescr
6: sysLocation
7: sysName

Mar 19, 2014

V4.2-5

2/13

Advertising