CAUTION

For changing the configuration parameters when using the Digital
Terminal interface, send the new values via radio through Datalogic
RF devices. Otherwise, send the $+CP0$-CR string via radio to set
the RS232 interface and define the parameters via serial interface.
This operation sets the RS232 parameters to default values and
erases the current header and terminator selection. Thus, after
configuration setting, you must restore the Digital Terminal interface,
Header and Terminator selection by sending a command string
similar to the one given in the following example:
$+CP512EA0141EA1102$-CR.



If you selected the Wedge interface, you should also send among the following
strings the one the matches your Keyboard Nationality:

English

$+FJ4$-CR

Deutsch

$+FJ3$-CR

Svenskt

$+FJ5$-CR

Français

$+FJ2$-CR

Italiano

$+FJ1$-CR

USA

$+FJ0$-CR

Español

$+FJ6$-CR

Belge

$+FJ7$-CR


STAR







 Modem Transmitter (Client)


RESTORE DEFAULT

Whenever necessary, send the following string to STAR

Modem™ via RS232 to

restore its default values:

Restore STAR







Modem™ Default

$+$*CR


This command does not change the STAR

Modem™ address nor the address of

the Stand Alone destination device, nor the RF Baud Rate parameters.