Configuring modem parameters, Configuring modem parameters -14, Configuring modem – Verilink SCM (880-503300-001) Product Manual User Manual
Page 52: Parameters

Administration Menu
4-14
Verilink SCM
R) SNMP read community string
This parameter is used as rudimentary security for messages to or
from an SNMP manager. This value should match the read
community string being used by the SNMP manager. Enter an
alpha-numeric string of up to 31 characters.
T) Ethernet type
There are two supported types: Ethernet 2 (DIX), and 802.3. If your
network uses TCP/IP, select DIX by entering “1”.
W) SNMP write community string
This parameter should match the write string being used by the
SNMP manager. Enter an alpha-numeric string of up to 31
characters.
P) Ethernet trap addresses
These are Ethernet addresses to which alarm messages will be sent.
The traphost may be Verilink’s Node Manager application or some
other SNMP network manager. You can specify up to four trap host
addresses.
E) SLIP trap addresses
These are IP addresses to which alarm messages will be sent via the
SLIP port. You can specify up to four addresses.
Configuring Modem Parameters
Modems used for SLIP connections can be configured and
controlled using the Modem Configuration Menu.
In addition to preconfigured parameters for the modem, the
Modem Configuration Menu provides a set of manual commands.
Access the Modem Configuration Menu by selecting the M option.