Nms connections, Network and dte connections, Alarm connections – Verilink 1051-2 Chassis (CG) Configuration/Installation Guide User Manual

Page 2: External clock connections, High-speed dte connections

Advertising
background image

T1

NET

1

T1

NET

2

T1

NET

3

T1

NET

4

T1

NET

5

T1

NET

6

T1

NET

7

T1

NET

8

T1

NET

9

T1

NET

12

ENET

T1

NET

10

T1

NET

11

1 2 3 4 5

1 2 3 4 5 6

2.4 AMPS

HIGH

SPEED

DTE

12

HIGH

SPEED

DTE

11

TB2 -

HIGH

SPEED

DTE

10

HIGH

SPEED

DTE

9

HIGH

SPEED

DTE

8

HIGH

SPEED

DTE

7

HIGH

SPEED

DTE

6

HIGH

SPEED

DTE

5

HIGH

SPEED

DTE

4

HIGH

SPEED

DTE

3

HIGH

SPEED

DTE

2

HIGH

SPEED

DTE

1

T1

NET

7

T1

NET

8

T1

NET

9

T1

NET

12

T1

NET

10

T1

NET

11

T1

NET

1

T1

NET

2

T1

NET

3

T1

NET

4

T1

NET

5

T1

NET

6

NMS A & NMS B, IN AND OUT, ARE NON-TELECOM (T1) CONNECTORS

Les portes d'entree/sortie NMS A & NMS B sont des connecteurs non-telecommunication (T1)

( A )

NMS
OUT

( A )

NMS

IN

( B )
NMS
OUT

( B )

NMS

IN

TB1

1 - EXT CLK
2 - EXT CLK
3 - ALARM RING

4 - ALARM TIP
5 - SIG GND

1 - +48V RTN ( B )
2 - FRAME GND
3 - -48V IN ( B )

4 - -48V IN ( A )
5 - SIG GND
6 - +48V RTN ( A )

TB2

TB1 -

TB2

NMS Connections

The NMS ports are used to connect the chas-
sis into the 8100A Site Controller. Within the
chassis, each unit is physically connected to
the next unit in a daisy chain. Two 6-pin
modular connectors are provided for both the
A and B sides.

All units in the
chain must use
the same NMS
bit rate, how-
ever, each unit
in the NMS
chain must
have a unique
address.

Network and DTE

Connections

The T1 DTE
and T1 NET
ports are 8-

pin modular

jacks. The
maximum
suggested
cable lengths
for chassis
connection
to the net-
work are listed in the following table. These
distances are based on a temperature of 70°F,
0.083

µ

F/mile capacitance, a 27 dB loss, and

a 100

, non-loaded, twisted pair cable.

Alarm Connections

Alarm conditions from all modules in the
chassis are bused together in parallel and are
presented on a single set of alarm relay con-
tacts (TB1, pins 3 and 4) allowing connection
to a remote indicating device. All modules in
a common chassis must operate in the nor-
mally open (NO) mode.

Connections to the contacts should use 20-
gauge stranded wire (or similar). The contacts
are rated at 120 mA (AC or DC).

Pin

NMS In

NMS Out

1

Not Used

Not Used

2

Signal Gnd

Signal Gnd

3

Data Out

Data Out

4

Data In

Not Used

5

Signal Gnd

Signal Gnd

6

Not Used

Not Used

Pin

T1 DTE T1 NET

1

Data Out

Data In

2

Data Out

Data In

3

Not Used

Not Used

4

Data In

Data Out

5

Data In

Data Out

6

Not Used

Not Used

7, 8

Signal Gnd

Signal Gnd

Cable Type

Loss per 1000'

Max Length

26-gauge

6.8 dB

3,900 ft

24-gauge

5.4 dB

5,000 ft

22-gauge

4.2 dB

6,400 ft

19-gauge

3.0 dB

9,000 ft

External Clock
Connections

TB1 provides the contacts allowing connec-
tion to an external timing source (pins 1
and 2).

High-Speed DTE
Connections

The high-speed port connections use a
female 25- pin subminiature DB-25 connec-
tor. The pin interface comparisons are de-
tailed in the table on the right.

If the unit is connected to an EIA-530 DTE
type device, only a one-to- one DB-25 cable
is required.

If the unit is connected to an RS-449 com-
patible interface, an adapter cable must be
used to match the 37-pin RS-449 standard.

The V.35 option also requires an appropriate
adapter cable to connect to devices that use
the standard 34-pin V.35 interface.

Common Name

DB-25

EIA-530

RS-449

V.35

Frame Ground

1

1

1

A

Signal Ground

7

7

19

B

Transmit Data (A)

2

2

4

P

Transmit Data (B)

14

14

22

S

Receive Data (A)

3

3

6

R

Receive Data (B)

16

16

24

T

Request to Send (A)

4

4

7

C

Request to Send (B)

19

19

25

Clear to Send (A)

5

5

9

D

Clear to Send (B)

13

13

27

Data Set Ready (A)

6

6

11

E

Data Set Ready (B)

22

22

29

Data Term Ready (A)

20

20

12

H

Data Term Ready (B)

23

23

30

Data Carrier Detect (A)

8

8

13

F

Data Carrier Detect (B)

10

10

31

Transmit Clock (A)

15

15

5

Y

Transmit Clock (B)

12

12

23

AA

Receive Clock (A)

17

17

8

V

Receive Clock (B)

9

9

26

X

Terminal Timing (A)

24

24

17

U

Terminal Timing (B)

11

11

35

W

145 Baytech Drive

San Jose, California 95134

127 Jetplex Circle

Madison, Alabama 35758

(800) 837- 4546

www.verilink.com

FAX-On-Demand

(800) 957-5465

Technical Assistance Center

(800) 285- 2755

Advertising
This manual is related to the following products: