Front Panel Description

STATUS: Green LED illuminates when the unit is powered. Red LED illuminates when an alarm
exceeding thresholds is detected or other unit failure.

ACO: Amber LED illuminates when the Alarm Cutoff switch is On (switch left) indicating that the
alarm relay contacts are forced to the No Alarms condition.

ACO SW: Alarm Cutoff switch controls the alarm relay circuitry. When the switch is On (left), the
circuitry is deactivated. The ACO indicator still functions normally.

ADDRESS: This 8-position switch (Switch 1) sets the address of the unit targeted by the command from
the EM8000 controller. Valid addresses are 0 through 253 with zero being the broadcast address and 253
reserved as a universal hailing frequency.

FORCE: Amber LED illuminates when the select switch is in either the A or B position. NMS
commands will not override this switch.

A / B: Green LEDs illuminate indicating which input (A or B) is being broadcast to the ports. If both
ports (A and B) have input, only the selected port’s indicator illuminates.

Select: The select switch forces the input to either the A (switch left) or B (switch right) input. N (switch
center) is for normal operation.

NMS BR: S2-1 and S2-2 set the NMS bit rate. Refer to the NMS Bit Rate table below for setting
information.

SUPV BR: S2-3 and S2-4 set the Supervisory port bit rate. Refer to the SUPV Bit Rate table below for
setting information.

LSB: S2-5 sets the Least Significant Bit with respect to the duplex select. Refer to the Duplex Select
table for setting information.

Duplex Select: S2-6 and S2-7 select the channel (1-12) that is full duplexed to the selected (A or B) input
channel. No channel is selected when set to zero. The expansion settings (A EXPD, B EXPD, and A/B
EXPD) full duplex back to their respective T1 input lines. For example, the A EXPD setting full duplexes
the return feed back to the T1 A input line; the B EXPD setting full duplexes the return feed back to the
T1 B input line; and the A/B EXPD setting full duplexes the return feed back to the respective T1 A and
T1 B input lines.

MSB: S2-8 sets the Most Significant Bit with respect to the duplex select. Refer to the Duplex Select
table for setting information.

Activity Indicators: The two red activity indicators allow you to identify transmission flow in the unit.
The left light indicates supervisory port transmission. The right light indicates NMS bus transmission.

SUPV: The supervisory port allow you to configure the unit’s software through a VT100 connection.

T

R

A

N

S

P

O

R

T

®

T

R

A

N

S

P

O

R

T

®

Specifications

Input/Output

Input (A/ B):

Impedance terminated

100

(± 2 %)

Unterminated 1000

Ext. Alarm Inputs: Off when

3 mA,

On when

>

4 mA and

20 mA

Output: Per

62411

waveform

into 100

Power

DC Power:

-48 VDC (±10%), 100

mA max.

2.5 Watts, 8.5 BTU

max.

Connection:

Terminal block

Mechanical

Mounting:

Desktop, wall, horizon-

tal rack, vertical rack
or vertical nest mount

Dimensions

Width:

1.72 in (4.37 cm)

Height:

6.8 in (17.27 cm)

Depth:

10.5 in (50.90 cm)

Weight:

4.0 lbs (1.81 kg)

Industry Standards

FCC Compliance: Part 15 Class A,

Subpart B

U.S. Safety:

UL 1950 Third Edition

Canadian Safety:

CSA C22.2
No. 950-95

1061 T1 Multicast

Configuration Guide

45-00117

1.00

NMS Bit Rate

NMS BR

S2-1

S2-2

19.2 kbps

B

B

9.6 kbps

A

A

2.4 kbps

B

A

1.2 kbps

A

B

SUPV Bit Rate

Bit Rate

S2-3

S2-4

19.2 kbps

B

B

9.6 kbps

A

A

2.4 kbps

B

A

1.2 kbps

A

B

Duplex Select

S2-5 S2-6 S2-7 S2-8

0

B

B

B

B

1

A

B

B

B

2

B

A

B

B

3

A

A

B

B

4

B

B

A

B

5

A

B

A

B

6

B

A

A

B

7

A

A

A

B

8

B

B

B

A

9

A

B

B

A

10

B

A

B

A

11

A

A

B

A

12

B

B

A

A

A Expd

A

B

A

A

B Expd

B

A

A

A

A/B Expd

A

A

A

A

1061

Multicast

ADDRESS

FORCE

ACO SW

ACO

STATUS

A

B

N

A

B

B

A

NMS BR

S

U
P
V

SUPV BR
LSB

DUPLEX SEL
MSB

Advertising