Connector Pinout

Pin

NMS Out

NMS In

EXPAND

T1 IN

Alarm/Power

1

Not Used

Not Used

Data Out

Data In

External Alarm A (+)

2

Signal Gnd

Signal Gnd

Data Out

Data In

External Alarm A (-)

3

Data Out

Data Out

Not Used

Not Used

External Alarm B (+)

4

Not Used

Data In

Data In

Data Out

External Alarm B (-)

5

Signal Gnd

Signal Gnd

Data In

Data Out

48 VDC Return

6

Not Used

Not Used

Not Used

Not Used

Alarm Common

7

Chassis Gnd

Chassis Gnd

-48 VDC

8

Chassis Gnd

Chassis Gnd

Frame Ground

9

Normally Closed

10

Normally Open

T

R

A

N

S

P

O

R

T

®

Rear Panel

8

1

8

1

10

1

1

81

8

UNTERM

48 VDC

Rear Panel Description

NMS (IN/OUT): These two ports connect the chassis to the TxPORT EM8000. Within the chassis, each unit
is physically connected to the next unit in a daisy chain. Each unit in the NMS chain must have a unique
address, however, they all use the same NMS bit rate.

Expand (A/B): These two 8-pin modular jacks expand the A or B inputs to other 1061 units providing
additional outputs. The maximum number of units is ten.

T1 IN (A/B): These two 8- pin modular jacks are used for the T1 input signal as well as the output of each
input. They output AIS with no input.

Terminate/Unterminate: These two slide switches set the A or B input. Terminate is used when the
expansion connector is not used. Unterminate is used when the expansion connector is daisy chained. The
recessed switches can be moved with a screwdriver. The last unit in a daisy chain must be terminated.

T1 Broadcast Port: This 50-pin female connector is used for the expanded outputs of either the A or B
inputs. Refer to the T1 Multicast Port Pinout table.

Alarm/Power: This 10-pin connector is used as a power and alarm connection. The unit requires a -48
VDC power source capable of supplying 100 mA current. The chassis ground lead is connected to pin 8. The
- 48 VDC lead is connected to pin 7. The return lead is connected to pin 5. The alarm connection is made on
pins 6 and 9 to operate in a normally closed mode (NC - opens on alarm) or on pins 6 and 10 to operate in a
normally open mode (NO - closes on alarm). The contacts are rated at 1.0 Amp AC or 1.0 Amp DC. 18 to 20
gauge wire is recommended. The external alarm connectors are unpowered, isolated inputs indicating
external alarms on inputs A and B. External alarm A is connected on pin 1 (+) and pin 2 (-). External alarm B
is connected on pin 3 (+) and pin 4 (-). They are 10 mA current loops and must be powered externally.

A

Tip Ring Function

1

26

Output # 1

2

27

Input # 1

3

28

Output # 2

4

29

Input # 2

5

30

Output # 3

6

31

Input # 3

7

32

Output # 4

8

33

Input # 4

9

34

Output # 5

10

35

Input # 5

11

36

Output # 6

12

37

Input # 6

13

38

Output # 7

26

50

25

1

14

39

Input # 7

15

40

Output # 8

16

41

Input # 8

17

42

Output # 9

18

43

Input # 9

19

44

Output # 10

20

45

Input # 10

21

46

Output # 11

22

47

Input # 11

23

48

Output # 12

24

49

Input # 12

25

50

Frame Gnd

Tip Ring Function

T1 Multicast Port Pinout

127 Jetplex Circle

Madison, Alabama 35758

Sales and Marteking

205-772-3770

800-926-0085

[email protected]

Returns/RMA

800-926-0085, ext. 2227

Technical Support

(205) 772-3770

800-285-2755

[email protected]

8

1

1

8

N
M
S
O
U
T

B

TERM

ALARM/
POWER

A

E
X
P
D

T1

A

-

I

N

N
M
S

I

N

B

E
X
P
D

T1

B

-

I

N

- - -

____