2010 rear panel – Verilink 2010 Standalone (CG) Configuration/Installation Guide User Manual

Page 2

Advertising
background image

TxPORT Customer Service

127 Jetplex Circle

Madison, Alabama 35758

Customer Service Returns:

800- 926-0085, ext. 227

Product Technical Support

(8 a.m. to 5 p.m. Central)

800-285- 2755 or

205- 772-3770, ext. 255

Emergency After Hours:

800-285- 2755

Manager: 205-603-2194

2010 Rear Panel

T

R

A

N

S

P

O

R

T

®

Switch S2 (front panel)

PRM

7

6

5

4

3

2

1

NET LBO

NET LBO

DTE ALBO

DTE ALBO

DTE ALBO

PRM

AIS

AIS

DTE ALBO

NET LBO

DTE ALBO

DTE ALBO

NET LBO

B

A

1 ESF Mode: 54016 - the unit responds only to 54016 CSU messages. T1.403 mode - the unit responds to

ANSI loop/unloop commands and generates a PRM every second, but will not respond to 54016 messages.

2

Network Line Coding: Sets the NET line coding (including conversion).

3 DTE Line Coding: Sets DTE line coding (including conversion)

4 Network Line Framing: Sets the CSU to the framing of the network line. In the ESF mode, the unit

responds to all T1.403 or 54016 messages.

5

DTE Line Framing: Sets the CSU to the framing of the DTE line.

7

Density (zero suppression mode): Enabled allows ones density control after 15 successive zeros from the
DTE (per TR62411). Disabled ignores density control and allows 175 zeros to pass towards the network.

S2 -1 S2 -2 Attenuation

A

A

0 dB

A

B

-7.5 dB

B A - 15.0

dB

B B - 22.5

dB

S2 - 3 S2 - 4 S2 - 5 Distance

A

A

A

0 -133

B

B

B

134- 266

A

B

B

267- 399

B

A

B

400- 533

A

A

B

534- 655

Power: The unit is operated from 20 -

56 VDC (80 mA at -24 VDC or 45

mA at -48 VDC).

Alarm: The alarm relay contacts are
configured for ‘normally open’ or
‘normally closed’ operation, depend-
ing on the alarm relay jumper setting
(requires optional alarm card).

Pin DTE

NET

1

Data Out

Data In

2

Data Out

Data In

4

Data In

Data Out

5

Data In

Data Out

7

Frame Gnd

Frame Gnd

8

Frame Gnd

Frame Gnd

DTE

NET

AIS

Remote Loopback

Loopbacks

DTE

NET

Local Loopback

The 2010 can be looped remotely by generat-
ing towards it a standard CSU line loopback
code (00001 repeating for Š 5 seconds,
framed or unframed). Once looped, the re-
ceived signal from the T1 facility (NET IN) is
regenerated and transmitted back to the T1 fa-
cility (NET OUT).

The 2010 can be unlooped remotely by gen-
erating towards it a standard CSU line unloop
code (001 repeating for Š 5 seconds, framed
or unframed). The 2010 responds to FDL
loop and unloop command messages.

Switch S1

1-2 Network LBO: Sets the network signal level of data transmitted towards the T1 facility. Refer to the table.

3-5 DTE ALBO: Sets the DTE line build out transmit value towards the customer equipment. The value

should match the cable length from the CSU DTE port to the attached equipment. Refer to the table above.

6 AIS Enable: Enables sending an alarm indication signal during an active payload loopback. A - generate

AIS to DTE during remote loop; B - Pass received network signal to DTE.

7 PRM Enable: Enables sending a PRM during an AIS. If the unit detects loss of sync from the DTE, an

unframed all ones signal is generated to the T1 facility. If Switch S2-6 is set to generate AIS and Switch
S1-1 is set for T1.403 operation, the unit interrupts the AIS signal with a PRM once a second.

Switch S2

Network LBO

DTE ALBO

RJ48C Interface

NOTE: The ‘A’ position is the fac-
tory default for all switch settings.
If a particular user configuration
requires that a switch be placed in
the ‘B’ direction, then mark this
sheet for future reference.

Pin DTE

NET

1

Data In

Data Out

2

Frame Gnd

Not Used

3

Data Out

Data In

4

Frame Gnd

Not Used

9

Data In

Data Out

11

Data Out

Data In

DB15 Interface (option)

Power and Alarm

Enable

Generate

Disable

Pass Data

Density

DTE framing

NET framing

DTE code

NET code

Op Mode

Density

DTE framing

NET framing

DTE code

NET code

Op Mode

7

6

5

4

3

2

1

Switch S1 (front panel)

Disabled

D4

D4

B8ZS

B8ZS

T1.403

Enabled

ESF

ESF

AMI

AMI

54016

B

A

Not Used

Not Used

DTE

8

1

8

1

NET

1+

V

2G

N

D

3–

V

4F

R

M

G

N

D

5A

L

M

6A

L

M

C

O

M

(DB1

5

A

v

ail)

1

6

Op

tion

(DB1

5

A

v

ail)

Op

ti

o

n

Advertising