Verilink 3131 (CG) (CG) Configuration/Installation Guide User Manual

Configuration guide, Front panel description, Front panel specifications

Advertising
background image

Front Panel Description

Index

Item Function

1

TEST

When this button is pushed once, the unit transmits five seconds of inband loop code out to the network (either LLB or V.54
depending on Switch S1-7). The indicator blinks green during transmission of the loop code. If Switch S2-8 is set to Clear Loop,
the data from the DTE is passed to the network and data from the network is passed to the DTE. The TEST indicator is solid
green in this mode. If Switch S2-8 is set to BERT, the test pattern last selected is transmitted toward the network. The received
pattern is compared and if it is error free, the TEST indicator remains green. If pattern errors are detected, the TEST indicator
turns red for a minimum of one second. The data ports are looped back toward the DTE during the test. If the TEST button is
pushed again, the unit transmits 5 seconds of inband loop down code and returns to normal operating mode. The TEST indicator
is then turned off.

2

LOOP

When this momentary pushbutton is pressed once, the unit activates a line loopback, looping the network receive data back to the
network, and looping the data from the DTE ports back to the DTE. The LOOP indicator is lit while the unit is in loop. If pushed
again, the unit clears the loop and turns off the LOOP indicator.

3

TEST

This 3-color LED flashes green when the unit is transmitting loop code. It is green continuously when BERT is on with no errors
or the unit is in a clear test. It is red when the BERT is on and is receiving errors.

4

LOOP

This amber LED light continuously when the unit is in a loop mode.

5

NET

This 3-color LED is green when the unit is in frame sync. It is amber when the unit is receiving a yellow alarm from the far end.
It is red when the unit is out of frame sync and/or LOS.

6

ALARM This red LED lights continuously when the unit is in an active alarm condition. It flashes if the switch configuration is invalid.

7

POWER This green LED lights continuously when power is applied to the unit.

3131

Configuration Guide

Part Number 45-00104

Rev 1.0

Front Panel

Specifications

Network Interface

Line Rate:

1.544 Mb/s (

±

50 ppm)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal:

0 to - 27 dB ALBO

Connection:

RJ-48C jack, 100 W (

±

5%)

Output Signal:

3.0 V (

±

10%) base- peak into

100

with protection

Line Build Out:

0, -7.5, - 15, -22.5 dB attenuation

Transient Voltage: 1000 V protection, fused in/out
Jitter Control:

Per TR 62411 and T1.403

Timing Source:

Internal, recovered line clock,
external DTE, T1 DTE

Ones Density:

B8ZS, Nx 56 bit stuffing,
alternate fill; TR62411

Equipment Interface

DTE Port:

V.35, 34-pin

Data Rate:

Synchronous, N x 56 kps or
N x64 kbps (where N = 1 to 24)

Clocking:

Internal, External, Oversample

Data Invert:

Independent selection each port

Management Interfaces

Supervisory Port

Connection:

8 - pin modular (RS-232)

Data Rates:

1.2, 2.4, 9.6, and 19.2 kbps

Diagnostics

Performance:

Monitoring per TR54016, T1.403

Network Loops: Line or payload loopback

Fractional Loop: Responds to inband V.54 loop

DTE Port Loops:Bidirectional loop to DTE or Net

BERT:

511 and clear test patterns toward
network or DTE ports

Alarms

Activation:

Programmable thresholds

Reporting:

Front panel LEDs, Call On
Alarm (COA)

Power

115 VAC:

0.12 A, 12 W max, 41 BTU max

Mechanical

Mounting:

Desktop or horizontal rack

Dimensions:

12" (30.48 cm) wide, 1.75" (53.34
cm) high, 9" (22.86 cm) deep

Weight:

4 pounds (1.814 kg)

Environmental

Operating Temp:

32

°

to 122

°

F (0

°

to 50

°

C)

Storage Temp:

-4

°

to 185

°

F (-20

°

to 85

°

C)

Humidity:

95% maximum (non-condensing)

Standards

TR 62411:

December 1990

TR 54016:

September 1989

ANSI T1.403:

1989

TR 54019A:

April 1988

Industry Listings

FCC Compliance: Part 15, Subpart B, Class A

FCC Part 68 Cert: FXKUSA-22083-DE-N

NRTL:

1459, 2

nd

Edition

IC/CSO3 Cert:

1653 6531 A

CSA Certified:

LR 62298 (22.5 NO 22.5-M90)

ALARM

NET

LOOP

TEST

TEST

LOOP

POWER

2

1

4

3

5

6

7

3131

T

R

A

N

S

P

O

R

T

®

T

R

A

N

S

P

O

R

T

®

Advertising