Verilink PRISM 4051 (WS) Configuration/Installation Guide User Manual

4051 dds csu/dsu, Configuration guide, Specifications

Advertising
background image

Specifications

Network Interface

Service Type:

DDS I and DDS II clear channel
conforming to TR62310

Operating Modes: Full duplex, point-to-point, multi-point

Line Rates:

56 kbps (DDS I) and 72 kbps (DDS II)

Loop Range:

Up to a 45-dB loss

Line Connection:

RJ-48S jack, 8-pin mod.

Timing Sources:

Network, DTE, and Internal

Equipment Interface

Sync Data Rates:

56 kbps (DDS I) and 64 kbps (DDS II)

Anti-stream Timer: Off, 10, 30, or 60 seconds

DTE Clocking:

Internal or External

DTE Connections: 34-pin V.35 (ITU) or 25- pin RS-232D

Clocking:

Internal or external

Diagnostics

Loopbacks:

CSU, V.54 (receive and send)

BERT:

511 pattern

Management Interfaces

Supv Connection: 8- pin modular (RS-232)

Data Rates:

1.2, 2.4, 9.6, and 19.2 kbps

Power

48 VDC:

chassis supplied; 65mA, 3.12W, 10.6 BTU max.

24 VDC:

chassis supplied; 140 mA, 3.36 W, 11.5 BTU max.

Connection:

5- pin DIN

Mechanical

Housing:

Verilink 1051 chassis

Mounting:

Rack mount

Dimensions (nom.): 9.38 (23.8 cm) long

6.63 inches (16.8 cm) high
1.38 inches (3.49 cm) wide

Weight:

1 pound (0.442 kg)

Environmental

Operating Temp:

32

°

to 122

°

F (0

°

to 50

°

C)

Storage Temp:

4

°

to 185

°

F (

20

°

to 85

°

C)

Humidity:

95% max. (non-condensing)

Compatibility

TR62310

TR41450

Internet Standards: RFC 1157 (SNMP)

RFC 1155 (SMI)
RFC 1213 (MIB -II)
RFC 1055 (SLIP)

MIB- II:

Device identification and interface performance
data. All applicable objects and reporting are
maintained by the 8100A Site Controller.

Industry Listings

FCC Compliance: Part 15 Class A, Subpart B, and Part 68

U.S. Safety:

UL 1950, 3rd edition

Canadian Safety:

CSA C22.2 No. 950-95

Industry Canada:

CS-03, Issue 8

45-00113

2.0

4051 DDS CSU/DSU

Configuration Guide

Front Panel Description

STATUS

When the green indicator is On, the
unit is powered and may be
operating normally.
When the red indicator is On, there
is a fault that exceeds alarm
thresholds or another type of unit
failure.

TD

This green indicator is On during a
mark condition on the high-speed
transmit-data line.

RD

This green indicator is On during a
mark condition on the high-speed
receive-data line.

RTS

This green indicator is On when the
request to send signal is active.

DTR

This green indicator is On when the
data terminal ready signal is active.

FAR/LOC In the FAR position, the 4051 sends

five seconds of the V.54 loop
pattern then switches to the 511
pattern.

In the middle position, the 4051
sends five seconds of V.54
loopdown code then returns to its
normal operating mode.
In the LOC position, the 4051
performs a network latching
loopback.

Activity
Indicators

These two, small recessed
indicators are just above the
supervisory connector and show
supervisory and network manager
port activity.

SUPV

The supervisory port provides
direct terminal access to control
and monitor the 4051.

NET LOS This red indicator is On during a

loss of signal from the DDS
network.

NET OOF This amber indicator is On when

the unit detects and out of frame
condition or receives OOF codes.

TST
LOOP

This amber indicator is On when
the network interface is in any loop.

TST
BERT

This indicator is On when a 511-bit
BERT is in progress.

TST ERR This indicator is On when BERT

pattern errors are detected.

DTE

Far End

DTE

Network

STATUS

4051

CSU/DSU

LOS

OOF

TD

RD

RTS

DTR

S
U
P
V

N
E

T

T
S
T

LOC

FAR

LOOP

BERT

ERR

D

T
E

Advertising