INSTALLATION

24

5.3.4

Frequency controller

If the hose pump is fitted with a frequency controller,
consider the following points:

Take precautions so the motor does not re-start
automatically after an unscheduled stop.
In the event of a power or mechanical failure,
the frequency controller controls the motor to
stop. When the cause of the failure is removed,
the motor can restart automatically. The
automatic restart can be dangerous in certain
pump installations.

All control cables outside the enclosure must be
shielded and have a cross sectional area
between 0.22 and 1 mm

2

. The shielding must

be connected to earth at both ends.

Maximum permissible loads [N] on the

pump connections

Force

Bredel 10

Bredel 15

Bredel 20

F1

600

600

600

F2

300

300

300

F3

120

120

120

WARNING
A frequency controller that is fitted without
the manual control
can start automatically
when power is applied.