9 parts list for bredel cip 40 and cip 50 pump – Watson-Marlow SP40 User Manual

Page 64

Advertising
background image

SPECIFICATIONS

61

Bredel CIP 50

2

When the product temperatures are above 60°C
(140°F) always use one shim less than indicated.
Always round up in number of shims.
For shimming in case of Bioprene hose contact your
Bredel representative.

11.1.9 Parts list for Bredel CIP 40 and CIP 50 pump
The pump should be delivered with the cam in pumping
position. The pumping position means that the cam is
fully turned in the opposite direction of the pump
direction. The CIP position means that the cam is fully
turned in the direction of the pump direction.
Installation positions indicated on the drawings
(page 66):
1.

Rotor position for CCW rotation (Counter
clockwise).

2.

Rotor position for CW rotation (clockwise).

3.

Pump lid position (option 1).

4.

Pump lid position (option 2).

5.

Pump lid position (option 3).

6.

Pump lid position (option 4).

Advertising
This manual is related to the following products: