7.2 Terminate dispensing


When the filler has completed the number of fillings asked for in F6: it stops automatically. If
<GO> is pressed again, the filler completes the programmed number of fillings once more.

If you want to stop the fillings, before the programmed number has been completed, press
<STOP>, and the filler stops after completing the filling in progress.
The filling series can be completed by pressing <GO>.

If you want to stop IMMEDIATELY, also in the middle of a filling, press <STOP> twice, and the
filler stops immediately.
The filling series can be completed by pressing <disp.>+<GO>, and the interrupted filling are
counted in.

7.3 Continuous run


MC12 can also control a filler as a pump so the pump runs continuously.

The pumping is started by pressing <pump>+<GO>.

The filler starts with the entered acceleration and runs up to the required number of revolutions
per minute.
The filler runs at this velocity until stopped by pressing <STOP>.

In Function 11 the current uncalibrated flow can be read.

If an exact flow read-out is required, the system must be calibrated. This calibration shall be
made as indicated in the next paragraph .

It is recommended to use a rather long filling for this calibration of the flow value.