WCC III Technical Guide

15-17

15. SAT 3C/D/F INSTALLATION

Typical System Configuration with SAT 3C

8

7

SAT ADDRESS

2
1

4

8

A 3 WIRE ROOM SENSOR WILL NOT
REQUIRE A LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

WattMaster Controls Inc.

BINARY
INPUTS

BINARY
INPUTS

L8

ON OFF

128

32
16

64

L4

L3
L2

L1

L6

L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14

L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF
PULSE INPUT

OPTION 1

TEST

OPTION 3
OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

A 2 WIRE ROOM SENSOR WILL REQUIRE
A 300 OHM LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

A 4 TO 20 mA SENSOR WILL REQUIRE A
50 OHM LOAD RESISTOR WHEN SET FOR
A 1 VOLT INPUT, OR A 250 OHM LOAD
RESISTOR WHEN SET FOR A 5 VOLT INPUT.

CURRENT
INPUT

THERMISTOR
INPUT

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

0 - 10V

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

PROGRAMMABLE CONTROLLER

SAT III

H

C

COM

CHANNEL

2

1

3 4

2

1

3 4

5 6 7 8

5 6 7 8

V

OUT

GND

L
O
A
D

+V

ATI

EACH CONTACT
IS RATED FOR
24VAC OR VDC
@ .5 AMP MAX

0-15VDC
OUTPUT

MIN LOAD
IS 1K OHM
RESISTIVE
VDC ONLY

TO THE REST OF SAT III
ON SAT LOOP 1 TO 60

24VAC

LINE

VOLTAGE

24VAC

LINE

VOLTAGE

TO THE REST OF SAT III
ON SAT LOOP 61 TO 120

TO THE REST OF SAT III
ON SAT LOOP 121 TO 180

TO THE REST OF SAT III
ON SAT LOOP 181 TO 239

(MASTER COMMUNICATIONS DEVICE)

OPTIONAL EXPANSION

TO THE ISP
(INTERNET SERVICE PROVIDER)
CONNECTION TO THE INTERNET
(BY OTHERS)

HIGH SPEED DSL / CABLE MODEM / ROUTER

ETHERNET
CABLE

WCCIII - MCD - Rear View

120V LINE

VOLTAGE

TYPICAL SYSTEM CONFIGURATION WITH SAT 3C

"D" MODE

"C" MODE

"C" MODE ADDRESSING NOTES
"C" MODE SAT III ADDRESSING STARTS
AT ADDRESS 8.
EACH "C" MODE SAT III TAKES UP
8 SAT III LOGICAL ADDRESSES.
A "C" MODE SATIII CAN COMMUNICATE
WITH 8 DEVICES TOTAL.

"D" MODE ADDRESSING NOTES
"D" MODE SAT III ADDRESSING STARTS
AT ADDRESS 4.
EACH "D" MODE SAT III TAKES UP 4
SAT III LOGICAL ADDRESSES.
A "D" MODE SAT III CAN COMMUNICATE
WITH 32 DEVICES TOTAL.

SAT IIICD

Communications Interface

TUC XMIT

ON OFF

ON OFF

SAT ADDRESS

1

STATUS

LOCAL SET

16

4

2

8

64
32

128

LOCAL SET DISABLE

OPTION 2

LOCAL SET

OPTION 1

TEST

BATT ON/ OFF

TUC REC

SAT XMIT

SAT REC

CONNECTION
FOR TUC LOOP

1 TO 8 UNITS

TO THE REST OF SAT III
ON SAT LOOP 1 TO 60

24VAC INPUT FOR UPS LOSS
OF POWER DETECTION

UP TO 4000 FT. OF
COMMUNICATIONS
WIRE MAX PER LOOP.

PRINTER PORT - LASER
PRINTER NOT SUPPORTED

ETHERNET
CABLE

C

OMRON
G5LE-14P
24VDC
CONTACT:
UL / CSA 10A250VAC

G5LE-14P
24VDC
CONTACT:
UL / CSA 10A250VAC

OMRON

OMRON
G5LE-14P
24VDC
CONTACT:
UL / CSA 10A250VAC

G5LE-14P
24VDC
CONTACT:
UL / CSA 10A250VAC

OMRON

OMRON
G5LE-14P
24VDC
CONTACT:
UL / CSA 10A250VAC

OE330-21

OPTION 4

OPTION 3