12

6651-2241

RS-422/485

Electrical specification

EIA RS-485, 2-wire or 4-wire twisted pair

Data rate

300 bit/s – 1.5 Mbit/s

Data format

9 – 12 bits

Protocol

Start-bit followed by 8-11 bits

Retiming

Yes

Turning time
(2-wire RS-485)

One t

bit

t

bit

= 1 / Baud rate (Baud rate in bit/s)

Transmission range

< 1200 m, depending on data rate and cable type (EIA RS-485)

Settings

120 W termination and failsafe biasing 680 W

Protection

Installation Fault Tolerant (up to ±60 V)

Isolation to

Status and Power port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 13)

Shielded cable

Not required

LED Indicators(for details see page 15)