Westermo ODW-730-F1 User Manual

Page 14

Advertising
background image

14

6651-2241

LED indicators

LED

Status

Description

PWR

Power

ON

Power is on.

OFF

Power is off.

FP

Not used

CH 2

Not used

CH 1

Channel 1 link status

ON

Fiber link to other unit has been estab-

lished at CH 1.

Flashing Optical power detected but link to other

unit has not been established at CH 1.

OFF

No optical power detected and no link

to other unit has been established at

CH 1.

TD

Flash

Data received on the electrical interface

and transmitted out on the optical inter-

face.

OFF

No data received on the electrical inter-

face.

RD

Flash

Data received on the optical interface

and transmitted out on the electrical

interface.

OFF

No data received on the optical interface.

FL R

Failure link remote

ON

Remote fibre link failure.
A fibre link is out of operation at any

other unit than this one*.

Flashing Hardware error or invalid configuration.

FL L

Failure link local

ON

Local fibre link failure.
A fibre link is out of operation at this

unit.

Flashing Hardware error or invalid configuration.

* Only valid if used togheter with ODW-720-F1 units in a multidrop network.
Note: During power up, all LED’s will turn on for about 1 second.