Switch settings ld-64, Turning time/data rate/ connected units, Selection of 2- or 4-wire – Westermo LD-64 User Manual

Page 17: Selection of master/slave, Selection of bits

Advertising
background image

17

6073-2002

Turning Time/Data rate/

Connected units

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

S1

ON

1 2 3 4 5 6 7 8 9

20

Number**

of units

20

20

20

20

20

20

15

10

5

Selection of 2- or 4-wire

4-wire

S1

ON

1 2 3 4 5 6 7 8 9

2-wire

S1

ON

1 2 3 4 5 6 7 8 9

Selection of Master/Slave

Slave

S1

ON

1 2 3 4 5 6 7 8 9

Master

S1

ON

1 2 3 4 5 6 7 8 9

Selection of bits

9

S1

ON

1 2 3 4 5 6 7 8 9

10

S1

ON

1 2 3 4 5 6 7 8 9

11

S1

ON

1 2 3 4 5 6 7 8 9

*

S1

ON

1 2 3 4 5 6 7 8 9

Selection of 2-wire RS-485 or 4-wire RS-422.
For RS-232 S1:1 can be ignored.

Switch settings LD-64

0.4 ms

2 400 bit/s

Turning-

time

Transmission*

rate

0.2 ms

4 800 bit/s

0.1 ms

9 600 bit/s

50 µs

19 200 bit/s

25 µs

38 400 bit/s

16 µs

62 500 bit/s

11 µs

93 750 bit/s

9 µs

115.2 kbit/s

6 µs

187.5 kbit/s

3 µs

375 kbit/s

* Use this setting for synchronous or other

asynchronous protocols.
The transmitter will be active from the
startbit to 10 bit-times after the last high
databit (see example below). The speed
shall be set to

10 times the required

communication speed.

Please note that only one master can be
used per system.

Start bit

1 bit = 52µs

1 bit: 1/19 200 = 52µs

Data rate 19 200

Transmitter active

Set the speed to 187.5 kbit/s

10x52µs = 520µs

Example 19 200 bit/s

*) For other speeds please contact

Westermo

**) For additional units please contact

Westermo

S1:3 not used