Selections of bits, Danger! do not open connected unit, Switch settings – Westermo MA-45 User Manual

Page 10: Selection of data rate

Advertising
background image

10

6045-2002

Selections of bits

S2

  9

S2

10

S2

11

S2

12

S1  Selection of power supply 115/230 V AC
S2   Selection of data rate 

Selection of 2- or 4-wire transmission 
Selection of no. of data bits  
(see table below)

S3   Selection of termination and fail-safe 

(see next page)

ON

OFF

S3

1 - 4

ON
OFF

S1

S2

1 - 8

DANGER! DO NOT OPEN CONNECTED UNIT

1 2 3 4 5

V.24/RS-232-C

CONNECTION

LINE

CONNECTION

Switch settings

The MA-45 can through different switch settings be adapted to a variety of running  
conditions. To set the switches, open the plastic case with e.g. a screw-driver.

ON 

 1  2  3 4  5 6  7 8

ON 

 1  2  3 4  5 6  7 8

ON 

 1  2  3 4  5 6  7 8

ON 

 1  2  3 4  5 6  7 8

Selection of data rate

It is not necessary to set the datarate or the number 
of bits when RTS-control is used.

S2

    1 200 bit/s

Data  

Rate

Turning 

time

S2

    2 400 bit/s

S2

    4 800 bit/s

S2

    9 600 bit/s

S2

  19 200 bit/s

S2

  38 400 bit/s

S2

  57 600 bit/s

S2

115 200 bit/s

780 µs

410 µs

220 µs

130 µs

48 µs

34 µs

22 µs

11 µs