Line connection transmission range (interface 2), Ma-45 dc specifications, Switch settings – Westermo MA-45 User Manual

Page 13: Connections, According to ma-45 ac, According to ma-45 ac, except power supply

Advertising
background image

13

6045-2002

Line connection

Transmission range (interface 2)

Use twisted pair cable. Max transmission range 1 200 metre.  
(cable specifications 0.3 mm² and capacitance 42 pF/m).
The transmission range will increase if a cable with lower capacitance and larger  
diameter is used. 
Use shielded cable in heavy industrial environments.

1) If shielded cable is used, connect the shield only at one end to avoid ground currents.

Twisted pairs

A’

B’

A

B

Transmitter

Receiver

MA-45

Receiver

Transmitter

Shield

1)

1
2
3
4
5

3
4
5

A/A’
B/B’

Transmitter/
Receiver

A/A’

B/B’

MA-45

Transmitter/

Receiver

2-wire

4-wire

Twisted pairs

RS-422

equipment

A

B

A’

B’

RS-485

equipment

Shield

1)

MA-45 DC
Specifications 

Power supply

12–36 V DC

Power consumption

Max 2 W

Insulation

1 000 V

Fuse F1

1.6 A fast 5x20 mm

All other specifications according to MA-45 AC

Switch settings

According to MA-45 AC

Connections

According to MA-45 AC, except power supply

Connection

no.

Power 

supply

1 

+ Voltage 

2 

– Voltage

3

1 2 3 4 5

V.24/RS-232-C

CONNECTION

LINE

CONNECTION

1 2 3

POWER

12-36VDC

Advertising