Ratings and safety control drawing – Westermo MCW-211 User Manual

Page 5

Advertising
background image

5

6645-2204

Ratings and safety control drawing

Power

(12 – 48) VDC; 200 mA

Ambient temperature

–25ºC ≤ Ta ≤ +70ºC

Maximum surface temperature

Temperatur class T4 (max 135 ºC )

Degree of protection

IP21

Installation spacing

Minimum 25 mm above / below and minimum 10 mm left / right

The FX port is selectable between SC, -ST or -LC
connection depending on variant of the model.

Power

Position

Direction/

descripton

Input/Output values

1

In / COM

U

in

= (10 – 60) VDC

Max

l

in

= 0.29 A @ 10 VDC

MaxP

In

= 3.6 W

2

In / +VA

3

In / +VB

Ethernet TX – RJ-45

Position

Direction*/

descripton

Input/Output values

1

In/Out / TD+

U

= ±1 V (4 µV/s)

l

= ±20 mA

Data rate:
10/100 Mbit/s

2

In/Out / TD–

3

In/Out / RD+

4

Not connected

5

Not connected

6

In/Out / RD–

7

Not connected

8

Not connected

* Galvanically isolated via signal transformers and capacitively

isolated to signal ground through 3 kV 470 pF capacitor.

Ethernet FX – SC, ST or LC

Position

Direction/

descripton

Input/Output values

Rx

In / Receive port

Max optical power = dBm
Data rate: 100 Mbit/s

Tx

Out / Transmit port