Type tests and environmental conditions

Electromagnetic Compatibility
Phenomena

Test

Description

Level

ESD

EN 61000-4-2

Enclosure contact

± 4 kV

Enclosure air

± 8 kV

RF field AM modulated

IEC 61000-4-3

Enclosure

10 V/m 80% AM (1 kHz), 80 – 2700 MHz

Fast transient

EN 61000-4-4

Signal ports

± 1 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Voltage dips
and interruption

EN 61000-4-29

DC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage

Radiated emission

EN 55022

Enclosure

Class A

Conducted emission

EN 55022

DC power ports

Class A

Dielectric strength

EN 60950

Signal port to other
isolated ports

1.5 kVrms 50 Hz 1 min

Power port to other
isolated ports

2 kVrms 50 Hz 1 min

Environmental
Temperature

Operating

–25 to +70ºC

Maximum surface
temperature

135°C (temperature class T4)

Storage & Transport

–40 to +70ºC

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz

Shock

IEC 60068-2-27

Operating

15 g, 11 ms

Packaging
Enclosure, MCW-211

UL 94

PC / ABS

Flammability class V-1

Enclosure, MCW-211 Ex

Cabelec 6141

Dimension W x H x D

35 x 121 x 119 mm

Weight

0.25 kg

Degree of protection

IEC 529

Enclosure

IP 21

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail