Marking – Westermo MDW-45 User Manual

Page 5

Advertising
background image

5

6617-2203

General
This unit is intended for use in Zone 2 hazardous location only.

Marking

II 3 G
Ex nA IIC 136°C (T3) Gc
SPECIAL CONDITION
WARNING – DO NOT SEPARATE WHEN ENERGIZED

ATEX Information (Applicable for MDW-45 LV EX only)

Indicate that this unit complies with relevant European standards that are
harmonised with the 94/9/EC Directive (ATEX).

II

Equipment group II.
This unit can be installed in all places with an explosive gas atmosphere other
than mines susceptible to firedamp.

3

Equipment category 3.
A category is the classification according to the required level of protection.
This unit ensures the requisite level of protection during normal operation
and is intended for use in areas in which explosive atmosphere caused by
gases, vapours, mists, or dust mixtures are unlikely to occure or, if they do
occure, are likely to do so only infrequently and for a short periode only.

G

Indicates protection concerning explosive atmospheres caused by gases,
vapours or mists (G).

Ex

Indicates that this unit is in conformity with relevant European Ex standard(s).

nA

The type of protection used.
This unit is a non-sparking device "nA" which is constructed to minimize
the risk of occurence of arcs or sparks capable of creating an ignition
hazard during conditions of normal operation.

IIC

Gas group, a typical gas i hydrogen.

136°C (T3)

Maximum surface temperature assigned = 136°C with the next highest
temperature class T3 (T3 = 200 °C).
This unit is classified in accordance with its maximum surface temperature
(external and internal).

Gc

Equipment protection level Gc (EPL Gc)
Equipment for explosive gas atmospheres, having a "enhanced" level of protec-
tion, which is not a source of ignition in normal operation and which may have
some additional protection to ensure that it remains inactive as an ignition
source in the case of regular expected occurences. EPL Gc are analogous to
the ATEX Categories (Category 3 G = EPL Gc).

SPECIAL

CONDITION

This unit has a special condition for safe use.
The special conditon for safe use contains safety related information that is
necesarry for the correct installation and safe use.

Advertising