Interface specifications – Westermo ODW-620-F1 User Manual

Page 11

Advertising
background image

11

6651-22621

Status

Port type

Signal relay, changeover contacts

Rated voltage

Up to 48 VDC

Operating voltage

Up to 60 VDC

Contact rating

500 mA @ 48 VDC

Contact resistance

< 50 mW

Isolation to

RS-232 and Power port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

* External supply current capability for proper startup

Interface specifications

Power

Rated voltage

12 to 48 VDC
24 VAC

Operating voltage

10 to 60 VDC
20 to 30 VAC

Rated current

300 mA @ 12 V
150 mA @ 24 V
75 mA @ 48 V

Rated frequency

DC: –
AC: 48 to 62 Hz

Inrush current I²t

0.2 A²s

Startup current*

1.0 Apeak

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

RS-232 and Status port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.

This earthing point should have a low impedance connection to the conductive enclosure of the apparatus

cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing

system of an installation and may be directly connected to the protective earth.

RS-232

Electrical specification

EIA RS-232

Data rate

300 bit/s – 250 kbit/s

Transmission range

15 m

Isolation to

Status and Power port

Connection

9-pin D-sub female (DCE)

Shielded cable

Not required, except when installed in railway applications as
signalling and telecommunications apparatus and located close
to rails*

Conductive housing

Isolated to all other circuits and housings