Westermo RM-80 User Manual

Page 41

Advertising
background image

41

6193-4201

Client Configuration

Perform the same configuration steps as the Access Point configuration with the follow-
ing differences:

… Connect straight through Ethernet cable between PC and RM-80.

… Ensure configuration PC and RM-80 are setup to communicate on the same network

… Set dipswitch to SETUP

… Power up unit, and wait for LINK led to cease flashing.

… Adjust PC network settings

Set Configuration PC network card with network setting of IP address 192.168.0.1, net-
mask 255.255.255.0

… Open configuration webpage with Internet Explorer at address http://192.168.0.1XX/

When prompted for password, enter default username “user” and password “user”
Enter “Quick Start”, and select Client.
Change the IP address to 192.168.0.53
Enter a System Generator String
Select the Radio Encryption required.
Set dipswitch to RUN.
Save the changes, and unit will reset. Wait for unit to complete reset.

… Open configuration webpage with Internet Explorer at address http://192.168.0.53/

Select Network settings menu option
When prompted for password, enter default username “user” and password “user”
Set the Gateway IP address to 192.168.102.54
Set the Ethernet IP address to 192.168.102.53, network mask 255.255.255.0
Set the Wireless IP address to 169.254.102.53, network mask 255.255.255.0

Click on button Save to Flash and Reset. Webpage will display that message indicating
details are being written to flash. Wait for RM-80 to reboot before removing power.

Extending range of a network with a Repeater hop

Configure units as described in Section Extending a wired network. Place the Access Point
at the remote intermediate repeater location.

6XXZhh