CHAPTER 9: DEBUGGER

br

(register break)

Function

This command sets or clears register break. This command allows you to specify data or a mask that
constitutes a break condition for each register (A, B, F, X, and Y). The program will break when all
setting conditions are met.

Format

(1) >br <register> <value> [<register> <value> [...<register> <value>]]

(direct input mode)

(2) >br

(guidance mode)

Register break set status

1. set

2. clear

…? <1 | 2>

(Command is completed when "2" is selected.)

A

Old value

: <value>

B

Old value

: <value>

FI

Old value

: <value>

FD

Old value

: <value>

FZ

Old value

: <value>

FC

Old value

: <value>

X

Old value

: <value>

Y

Old value

: <value>

>

<register>: Register name; A, B, F, X or Y
<value>:

Data pattern for the register; hexadecimal or binary with 'B' suffix (* can be used for the bits to
be masked)

Examples

Format (1)

>br F ***1B

... Sets a register break condition so that the program breaks when the C flag is set.

Format (2)

>br

Register break: None
1. set 2. clear ...? 1

... "1. set" is selected.

A - : a

... Data 0xa is set for A register condition.

B - : *

... "*" masks the register condition.

FI - : 1

FD - : *

FZ - : 0

FC - : *

X - : 20

Y - : ^

... "^

" returns guidance to previous setting.

X 020 : 60

Y - : *

>br

A:A B:* X:060 Y:* IDZC:1*0*B
1. set

2. clear ...? 2

... "2. clear" is selected.

>br

Register break: None
1. set

2. clear ...?

... Terminated by [Enter] key.