7-2 Installing the Optional Level Sensor

Rotary level sensing devices monitor the material level in the chamber, providing an
automatic cutout in case of over-filling.

Use the following procedure to install the optional level sensor:

5. Open the two toggle fasteners at the discharge box.

6. Remove the discharge box.

7. Remove the stopper at the rear of the discharge box.

8. Remove the cotter at the vane of the level indicator.

9. Pull out the vane.

10. Unscrew the lock nut.

11. Mount the level indicator in the discharge box.

12. Mount the lock nut and tighten.

13. Mount the vane at the level indicator.

14. Mount the cotter.

15. Replace the discharge box.

Close the two toggle fasteners at the discharge box.



























4 Inch Granulator

Chapter 7: Appendix