14. A) Install the 1/4”Barb x 1/8”NPT fitting
(#14) into the Airaid Modular Intake Tube
(MIT) (#5).
B) Next, slip the 1/4”x 4” hose (#16) onto the

10. A) Using a 10mm socket, remove the two
nuts and remove the beauty cover. (Save for
reinstallation.) B) Remove the bolt thru the
Adel clamp for the air conditioning hose. C)
Loosen the hose clamp on the factory intake
tube at the throttle body and the airbox if it
was tightened in step #5.

11. A) Disconnect breather hose at the valve
cover. B) Disconnect 1/4” and 1/8” vacuum
lines on the back of the factory intake tube. C)
Unclip MAF wire harness retainer from the
intake tube. D) 01-03 Sequoias and 00-02
Tundras only; remove 3/8” vacuum hose be-
tween factory intake tube and metal fitting on
top of the intake manifold. (Hose Not Shown)

12. Remove the factory intake tube.

15. Install the Airaid MIT (#5) into the hump
hose first, and then into the coupler. Adjust the
MIT snugly against the thr ottle body and
tighten all four clamps. Install the supplied
button head bolt (#20), and washer (#21) thru
the Adel clamp, and thread into the MIT. (See
arrow)

Airaid Filter Co. 2688 E Rose Garden Ln. Phoenix AZ 85050 (800) 498-6951

[email protected]

www.airaid.com

REV.10.25.13

P/N 790-551 Aerosol Spray
P/N 790-550 Squeeze Spray

A.

.

B.

C.

13. A) Install the urethane hump hose (#7)
onto the MAF adapter (#4). Use the #56 hose
clamp (#12) on the MAF adapter end, and the
#60 hose clamp (#13) on the intake tube end.
B) Install the reducer coupler (#6), small end
towards the throttle body with two #52 hose
clamps (#11). Leave the clamps loose for now.

B.

A.

Thank you for purchasing the Airaid Intake System. Contact Airaid @ (800) 498-6951 8:00 AM - 5:00 PM MST weekdays for questions regarding fit or instructions

that are not clear to you. Your Airaid Intake System was carefully inspected and packaged. Check that no parts are missing, or were damaged during shipping. If any parts are
missing, contact Airaid. The air filter element is protected from direct exposure to water and debris; care should be taken not to drive through deep water. WATER INGESTION
IS THE DRIVERS RESPONSIBILTY! The air filter is reusable and should be cleaned periodically.

A.

.

B.

C.

D.

16. 03-04 Tundra, 04 Sequoia
A) Install the 1/2”x13” breather hose (#8)
from the MIT to the valve cover. B) Install
the 1/4” x 1/4” x 1/8” vacuum tee (#15) into
the 1/4” x 4” hose (#16) and then into the
factory 1/4” vacuum hose, and 1/8” vacuum
hose as shown. Refer to the hoses in step
#11. Reinstall the beauty cover from step
#10.

18. Double check your work!

Make sure there is no foreign material in the
intake path. Make sure all clamps, hoses, bolts,
and screws are tight.

19. Reconnect the negative battery
cable!

A.

B.

17. All Other Applications
A) Install the 1/2” x 13” breather hose (#8),
from the MIT to the valve cover. B) Cut the
1/4” x 4” hose in half, and install the 1/4” x 1/4”
x 3/8” tee (#23) between the two halves. Con-
nect the 3/8”x 17” hose (#9) between the tee,
and the factory metal fitting above the intake
manifold. Squeeze the speed clamp (#24) over
the hose at the factory metal fitting. (not shown)
C ) Install the vacuum tee (#15) into the 1/4” x
4” hose (#16) and then into the factory 1/4”
vacuum hose, and 1/8” vacuum hose as shown.
Refer to the hoses in step #11. Reinstall the
beauty cover from step #10.

A.

B.

A.

B.

C.

FILTER IDENTIFICATION

700-458 Airaid Oiled Media 701-458 Airaid SynthaMax Dry Media - Red

702-458 Airaid SynthaMax Dry Media - Black 703-458 Airaid SynthaMax Dry Media - Blue

For your Oiled media filter we suggest

using the AIRAID Filter Tune-Up Kit!

Synthamax Air Filters do not require oil.
Service air filter as needed by cleaning
with common non-petroleum all-purpose
household cleaner and water. Simple
Green®, Formula 409® or equivalent
works great. Apply cleaner to outside of
air filter and allow to soak. Then flush
filter clean from the inside out with a gar-
den hose and repeat steps if necessary.
Do not apply high pressure water or air
to clean filter. Allow filter to air dry and
reinstall

.