Airmar NMEA 2000® Depth, Датчики User Manual
Page 29

DST200 User Manual revision 1.000
Proprietary and Confidential
27
This PGN does not respond to ISO Requests (PGN 59904).
Although this is a fast-packet message, the version with this PID fits into a single CAN frame.
To change the Temperature Offset, use the Command Group Function PGN 126208, specifying the individual fields in PGN 126720-42 as follows.
PGN 126720
Field Value
1
135 (decimal)
3
4 (decimal)
4
42 (decimal)
5
Desired temperature instance
7
Desired temperature offset
If a Command Group Function PGN 126208 is received to change field 7 to a value outside the range of allowable values, the response will be an Acknowledge Group Function
PGN 126208 with a parameter error code indicating 'Request or command group parameter out-of-range.'