Temperature filter type 0 (no filter) – Airmar NMEA 2000® Depth, Датчики User Manual
Page 37

DST200 User Manual revision 1.000
Proprietary and Confidential
35
Temperature Filter Type 0 (No Filter)
For Temperature Filter Type 0, the fields in PGN 126720-44 starting with field 5 are described below.
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
5 Filter type
Yes
N/A DF52 4 bits
1
0 = no filter
See remark for field 5 on page 33.
6 Reserved
No
DD001 DF52 4 bits
1
0xF
All bits set to logic “1”
7 Sample interval
No
N/A DF66 uint16
0.01 s 0 to 655.32 seconds
0 = reserved
0xFFFE = restore default
0xFFFF = data not available
/ do not change
Interval of time between successive samples
of the water temperature thermistor.
This field is stored in EEPROM and may be
changed with the Command Group Function
PGN 126208. The default value for filter type
0 is 1.00 seconds.
Temperature Filter Type 0 causes the Water Temperature value reported in PGNs 130310 and 130311 to be calculated using only the thermistor reading(s) taken in the most recent
sample interval. No filtering of the data is performed.
To select temperature filter type 0 and specify the sample interval, use the Command Group Function PGN 126208, specifying the individual fields in PGN 126720-44 as follows.
PGN 126720
Field Value
1
135 (decimal)
3
4 (decimal)
4
44 (decimal)
5
0 (filter type)
7
Desired sample interval