6position on farming machine – ARAG Bravo 300s series computers crop spraying - Direct connection - INSTALLATION User Manual

Page 6

Advertising
background image

6

*

6

pOSitiON ON FARMiNg MAchiNE

6.1

System recommended composition

DIRECT CONNECTION

Assembly diagram for crop sprayers with membrane pump

Legend:

A Bravo 300S
b Battery
D

Filling pump

F Flowmeter
g

Main valve

M Pressure sensor
p

Control valve

R

Foam marker

S

Speed sensor

t

Filling flowmeter or

Pump Protector

X

RPM sensor or Pump Pro-

tector
1÷5 Section valves

DIRECT CONNECTION

Assembly diagram for crop sprayers with centrifugal pump

Fig. 3

Legend:

A

Bravo 300S

b Battery
D

Filling pump

F Flowmeter
M Pressure sensor
p

Control valve

R

Foam marker

S

Speed sensor

t

Filling flowmeter

X

RPM sensor

1÷5 Section valves

The computer must be directly connected to the farming machine battery.

*

Do not connect the computer to key-operated switch (15/54).

*

Fig. 2

*

Advertising