7technical data, 8disposal at the end of service – ARAG ORION Visual Flow User Manual

Page 12

Advertising
background image

12

7

TECHNICAL DATA

Description

Orion Visual Flow

Power supply

11 ÷ 14,5 Vdc

Max. absorption

300 mA

Minimum conductivity of liquid

300 µScm

Working temperature

0 °C ÷ 60 °C

+32 °F ÷ +140 °F

Storage temperature

-20 °C ÷ 60 °C

-4 °F ÷ +140 °F

Dimensions

100x200x126 mm

Weight

886 ÷ 1650 g (depending on the type)

Flowrate

Internal passages

(Ø mm)

Pulses/liter

l/min

US GPM

pls/l

pls/GAL

1 ÷ 20

0,3 ÷ 5

7

3000

11355

2,5 ÷ 50

0,6 ÷ 13

10

1200

4542

5 ÷ 100

1,3 ÷ 26

14

600

2271

10 ÷ 200

2,6 ÷ 53

18,5

300

1135

20 ÷ 400

5 ÷ 106

28

150

568

30 ÷ 600

8 ÷ 158

28

100

378

Models (*)

Max pressure

(bar)

Materials

Legend:

4621BAx1x1x

20

N + P + A

N = Nylon
P = Polypropylene
A = Inox stainless steel
O = Brass

4622BAx1x1x

20

N + P + A

4622BAx7x1x

20

N + P + A

4621BAx3x3x

40

N + P + A + O

Typical error

± 0,5% of maximum value

Maximum error

± 1% of maximum value

(*) = 'x' stays for all possible variations of that position.

8

DISPOSAL AT THE END OF SERVICE

Dispose of the system in compliance with the established legislation in the country of use.

Tab. 4

Tab. 5

Tab. 6

Tab. 3

Advertising