PRODUCT DESCRIPTION

DigiWolf is a paddle flowmeter capable of measuring the rate of a fluid in a hydraulic circuit, and it can display the results of these measurements.
The device can also be set to control the filling of a tank by stopping the introduction of liquid once the required quantity has been reached (this function
is possible only by connecting the flowmeter to the Pump Stop Module or the relevant cable - Par. 2.4-2.5).

1.1

Intended use

This device is designed to work on agricultural machinery for crop spraying applications.
The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and
farming machines), harmonized with 2004/108/EC Directive.

The flowmeter must not be used to measure the passage of hydrocarbons, flammable, explosive or toxic liquids. The flowmeter
is not suitable for contact with liquids for human consumption.

2

FlOwmETER ASSEmBlY

Install the flowmeter

at least 20 cm from the elements that could cause turbulence inside the tubes (valves, bends, constrictions, etc.).

The flowmeter can be installed in a vertical or horizontal position.

CAUTION:
- Do not fit the flowmeter with the display facing down (Fig. 1).
- The system must have a filtering element with a filter of at least 50 mesh, together with a safety valve to limit use pressure at
the specified max. valve (Tab. 2 - Par. 2.3.1).

OK

NO!

OK

OK

Assemble the flowmeter using the suitable mounting parts (Fig. 2): fit the bolts (M8) in their seats, then make them slide to their stop position to prevent
them from coming out.

The flowmeter body must be assembled with the arrow on the label facing the flow direction.

APPROXIMATE CONSTANT