Setup, Amount measured by device, Actually delivered quantity – ARAG DIGIWOLF - Battery powered version User Manual

Page 11: Bd a, X [constant indicated on flowmeter body

Advertising
background image

11

4.1.2

Manual calibration

To set the flowrate constant manually, calculate and set the correct constant using the following formula:

[amount measured by device]

[actually delivered quantity]

Calibration

Man. calibration

Auto calibration

600

1) Access Manual calibration menu (Setup menu > Calibration > Man. calibration).

In Calibration menu, selecting Manual calibration, under the item the curren-
tly set constant will be displayed.
Press

OK

to access value modification.

Flowrate constant

Min value

Max value

C

1

50000

B

D

A

0600

0

2) Using the suitable keys, set the value of the flowmeter constant:

A)

Press to toggle from one digit to another

B)

Press in succession to modify the value of the digit highlighted by the cursor

C)

Press to save changes or

D)

Press to exit current page without confirming

changes. Refer to the label on the body (Fig. 21).

The flowmeter body must be assembled with the arrow on the label
facing the flow direction.

CODE

Approximate constant

4628405

250

4628506

132

4628707

64

APPROXIMATE CONSTANT

XXX

APPRO

XIMAT

E CON

STANT

XXX

Fig. 19

Fig. 20

Fig. 21

x [constant indicated on flowmeter body]

Tab. 3