5maintenance / diagnostics / repairs – ARAG ORION Tank filling system User Manual
Page 12

12
5
MaintenanCe / diagnOStiCS / RePaiRS
- At the end of each treatment, run clean water through the duct.
- In case of malfunction, and at any rate at the end of every season, clean the tank filling system
pipe with a special detergent.
- do not use metal or abrasive objects for cleaning the duct.
- do not use solvents or petrol for cleaning the external parts of the container.
5.1
troubleshooting
fault
CauSe
ReMedy
The valve leaks or the seal of the
ball is not enough
Presence of foreign bodies
• Make sure there are no foreign bodies;
if so, remove them.
Worn seals
• Contact the nearest Assistance Centre.
The valve does not work
Lack of power
• Check the connections, the cables, and
the controls. Replace the cable.
If the problem persists, contact your
nearest service centre.
Geared motor broken
• Replace the geared motor. The
instructions can be found on our Website
www.aragnet.com - ADDIN D30025
The valve does not stop at the
preset point
Malfunction of the microswitches
in the geared motor
• Contact the nearest Assistance Centre.
The flowmeter does not read any
value
No power supply
• Check the flowmeter wiring.
The value read by the flowmeter is
not linear or stable
Presence of turbulence or air in
the circuit
• Check the circuit.
The flowmeter shows incorrect data
Incorrect programming
• Check programming concerning the
displayed data.
Problems with the flowmeter
• Contact the nearest Assistance Centre.
The flowmeter shows the message
È stato raggiunto il valore di
fondoscala
• Reset the display following the
procedure described in the section on the
displayed value.