teCHniCal data

description

tank filling system

Power supply

11 ÷ 14,5 Vdc

Max. absorption

3,3 A

Minimum conductivity of liquid

300 µScm

Valve activation time

2,3 s.

Working temperature

0 °C ÷ 60 °C

+32 °F ÷ +140 °F

Storage temperature

-20 °C ÷ 60 °C

-4 °F ÷ +140 °F

Dimensions

375x200x346 mm

Weight

4100 g

flowrate

internal passages

(Ø mm)

Pulses/liter

l/min

uS gPM

pls/l

pls/gal

1 ÷ 20

0,3 ÷ 5

7

3000

11355

2,5 ÷ 50

0,6 ÷ 13

10

1200

4542

5 ÷ 100

1,3 ÷ 26

14

600

2271

10 ÷ 200

2,6 ÷ 53

18,5

300

1135

20 ÷ 400

5 ÷ 106

28

150

568

30 ÷ 600

8 ÷ 158

28

100

378

typical error

± 0,5% of maximum value

Maximum error

± 1% of maximum value

7

diSPOSal at tHe end Of SeRviCe

Dispose of the system in compliance with the established legislation in the country of use.

Tab. 1

INFORMATION TO USERS – PROFESSIONAL WEEE RECYCLING
This product complies with European Directive 2002/96/EC and subsequent mo-
difications.
At end-of-life and for disposal, the device must be taken to a waste recycling cen-
tre for electrical and electronic waste, or returned to the seller when buying a new
equivalent device.
The user is responsible for its transfer to the appropriate collection facilities.
For more detailed information concerning the collection systems available contact
your local waste disposal service.

Advertising