7435 and 9455 parameter table – Ensemble Designs 9455 3G Clean and Quiet Protection Switch User Manual
Page 13

www.ensembledesigns.com
7435 and 9455 - page 13
Model 7435 and 9455 Clean and Quiet Protection Switches
CONTROL
AVENUE PC or TOUCH SCREEN DEFAULT
Auto Reset
On
Off
On
Reset Time
0 - 120 seconds
15 seconds
TRS Test
Off
Lenient
Strict
Lenient
Audio Detect
On
Off
Off
Black Detect
On
Off
On
Freeze Test
Off
On
Sec Test Enable
On
Off
On
Window
Small
Big
Big
Black Time
0.1 - 300 sec
3 sec
Detect Level
0 - 100 IRE
10 IRE
Black Fraction
0 - 100%
95%
Audio Group
Group 1
Group 2
Group 3
Group 4
Group 1
Group Detect
Detect
Off
Detect
Audio Threshold
0VU
-5 VU
-10 VU
-15 VU
-20 VU
-25 VU
-30 VU
-35 VU
-40 VU
-20 VU
Audio Time
.5 - 300 sec
3 sec
Audio Channel
enable
Ch1 enable/disable
Ch2 enable/disable
Ch3 enable/disable
Ch4 enable/disable
Ch5 enable/disable
Ch6 enable/disable
Ch7 enable/disable
Ch8 enable/disable
Ch9 enable/disable
Ch10 enable/disable
Ch11 enable/disable
Ch12 enable/disable
Enabled
Enabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
7435 and 9455 Parameter Table