Replacing a power monitoring module – H3C Technologies H3C S12500 Series Switches User Manual
Page 89

79
Replacing a PEM (applicable to only the S12504 AC power
supply)
Only the S12504-AC requires the PEM replacement.
To replace the PEM:
1.
Use a Phillips screwdriver to loosen the screws on the front panel of the PEM.
2.
Slowly pull the PEM out along the slide rails, as shown in
.
3.
Put the removed PEM on an antistatic mat or in its original shipping materials.
4.
Unpack a new PEM, and slowly insert the PEM along the slide rails until the PEM has close contact
with the power frame backplane, as shown in
.
5.
Use a Phillips screwdriver to fasten the screws on the PEM panel.
Figure 61 Replacing the PEM
A: PEM to be removed
B: PEM to be installed
Replacing a power monitoring module
To replace the power monitoring module:
1.
Remove the power monitoring module.
a.
Loosen the captive screws on the power monitoring module.
b.
Pull out the power monitoring module slowly along the slide rails.
3
4
1
2
B
A