31

# Permit members in the default zone to access each other. By default, the server and disk belong

to the default zone and members in the default zone are not permitted to access each other. For
more information about zones, see "

Configuring FC zones

."

[SwitchA] vsan 10

[SwitchA-vsan10] zone default-zone permit

[SwitchA-vsan10] quit

[SwitchA] vsan 20

[SwitchA-vsan20] zone default-zone permit

[SwitchA-vsan20] quit

2.

Configure Switch B in the same way Switch A is configured.

Verifying the configuration

# Display member interfaces of each VSAN on switches, for example, Switch A.

[SwitchA] display vsan port-member

VSAN 1:

Access Ports:

Trunk Ports:

VSAN 10:

Access Ports:

Trunk Ports:

Vfc1

Vfc4

VSAN 20:

Access Ports:

Trunk Ports:

Vfc2

Vfc4